CAD (0)
  • Cart is empty
Air Cooled, non water heating assist dehumidifiers are used when there is a primary pool and spa water heating source such as a hot water boiler in place.Typical applications would include, but be limited to, small pool surface area projects or in coldclimates or both.
Unit of Measure

Available Model Configurations

N/A DCA4100Y: Air Cooled DCA4100Y-CT: Water Cooled

Standard Features

N/A

 - 3 Year Parts Warranty  - ElectroFin Coated Coils  - Low Ambient Head Pressure Control  - Listed to UL 60335-2-40  - Motorized Evaporator Bypass Damper  - Powder Coated, Galvannealed Steel Cabinet  - Remote Condenser Ready  - Rifle Tube Refrigeration Coils  - Single Refrigeration Circuit  - Single Scroll Compressor  - Stainless Steel Condensate Drain Pan  - Standard Microprocessor Control System (WH Models only)  - TEFC Blower Motor

Optional Features

N/A

- Control Options  - Defrost Timer Package  - Extended Surface Filters 2" & 4"  - External Static Upgrade  - Other Options Available  - Outdoor Installation Package  - Outdoor Make Up Air Assembly with Damper & Filter  - Remote Ready Delete  - Right Side Component Service Access  - Space Heating Options Available  - Top or Bottom Discharge (Not Field Convertible)  - Water Cooled Condenser for Water Heating or A/C Available

Available Voltage/Phase

N/A 208/230-3-60 460-3-60 575-3-60

Compressor @ 208/230-3-60

N/A 107500 BTU28.5 RLA255 LRA

Blower Motor @ 208/230-3-60

N/A 2 hp6.6 Unit FLA

Unit FLA @ 208/230-3-60

N/A 36.8

Maximum Fuse Size @ 208/230-3-60

N/A 60

Minimum Circuit Ampacity @ 208/230-3-60

N/A 43.9

Operating Power @ 208/230-3-60

N/A 9.83 kW

Compressor @ 460-3-60

N/A 107500 BTU13.5 RLA123 LRA

Blower Motor @ 460-3-60

N/A 2 hp2.9 Unit FLA

Unit FLA @ 460-3-60

N/A 17.2

Maximum Fuse Size @ 460-3-60

N/A 30

Minimum Circuit Ampacity @ 460-3-60

N/A 20.6

Operating Power @ 460-3-60

N/A 9.59 kW

Compressor @ 575-3-60

N/A 107500 BTU28.5 RLA255 LRA

Blower Motor @ 575-3-60

N/A 2 hp2.3 Unit FLA

Unit FLA @ 575-3-60

N/A 13.7

Maximum Fuse Size @ 575-3-60

N/A 25

Minimum Circuit Ampacity @ 575-3-60

N/A 16.4

Operating Power @ 575-3-60

N/A 9.58 kW

CFM

N/A 4100

Nominal Tonnage

N/A 8.7
Moisture Removal @ 82°DB / 50% R.H.1 N/A 39.2 LB/HR

Moisture Removal @ 82°DB / 60% R.H.1

N/A 49.8 LB/HR
Sensible Cooling @ 82°DB / 50% R.H.2 N/A 59.7 MBH

Sensible Cooling @ 82°DB / 60% R.H.2

N/A 53.3 MBH

Weight

N/A 1260 LB

External Static Pressure

N/A 0.5 " H2O

Refrigerant

N/A R-454B (Factory Charged 65 lbs.)

Compressor Type

N/A Scroll

Filter (Quantity: 4)

N/A 20" x 25" x 1" Fiberglass

Drain Connection

N/A 1" Bar Drain
Liquid Inlet [O.D.] (up to 50')3 N/A 0.625 in

Hot Gas Outlet [O.D.] (up to 50')3

N/A 1.125 in

Note

N/A Ratings are subject to change without notice
  • 1 Reheat Mode assuming 1050 BTU/lb
  • 2 Cooling Mode with Remote Condenser at 95 °F
  • 3 Over 50 ft contact factory