Available Model Configurations |
N/A DCA3000Y: Air Cooled DCA3000Y-CT: Water Cooled |
Standard Features |
N/A
- 3 Year Parts Warranty - ElectroFin Coated Coils - Low Ambient Head Pressure Control - Listed to UL 60335-2-40 - Powder Coated, Galvannealed Steel Cabinet - Remote Condenser Ready - Rifle Tube Refrigeration Coils - Single Refrigeration Circuit - Single Scroll Compressor - Stainless Steel Condensate Drain Pan - Standard Microprocessor Control System (WH Models only) - TEFC Blower Motor |
Optional Features |
N/A
- Control Options - Defrost Timer Package - Extended Surface Filters 2" & 4" - External Static Upgrade - Motorized Evaporator Bypass Damper - Other Options Available - Outdoor Installation Package - Outdoor Make Up Air Assembly with Damper & Filter - Remote Ready Delete - Right Side Component Service Access - Space Heating Options Available - Top or Bottom Discharge (Not Field Convertible) - Water Cooled Condenser for Water Heating or A/C Available |
Available Voltage/Phase |
N/A 208/230-3-60 460-3-60 575-3-60 |
Compressor @ 208/230-3-60 |
N/A 77800 BTU24.4 RLA200 LRA |
Blower Motor @ 208/230-3-60 |
N/A 1.5 hp4.5 Unit FLA |
Unit FLA @ 208/230-3-60 |
N/A 30.4 |
Maximum Fuse Size @ 208/230-3-60 |
N/A 50 |
Minimum Circuit Ampacity @ 208/230-3-60 |
N/A 36.5 |
Operating Power @ 208/230-3-60 |
N/A 7.15 kW |
Compressor @ 460-3-60 |
N/A 77800 BTU11.9 RLA103 LRA |
Blower Motor @ 460-3-60 |
N/A 1.5 hp2.2 Unit FLA |
Unit FLA @ 460-3-60 |
N/A 14.0 |
Maximum Fuse Size @ 460-3-60 |
N/A 25 |
Minimum Circuit Ampacity @ 460-3-60 |
N/A 17.9 |
Operating Power @ 460-3-60 |
N/A 7.12 kW |
Compressor @ 575-3-60 |
N/A 77300 BTU9.4 RLA78 LRA |
Blower Motor @ 575-3-60 |
N/A 1.5 hp1.9 Unit FLA |
Unit FLA @ 575-3-60 |
N/A 12.0 |
Maximum Fuse Size @ 575-3-60 |
N/A 20 |
Minimum Circuit Ampacity @ 575-3-60 |
N/A 14.4 |
Operating Power @ 575-3-60 |
N/A 7.24 kW |
CFM |
N/A 3000 |
Nominal Tonnage |
N/A 6.3 |
Moisture Removal @ 82°DB / 50% R.H.1 | N/A 29.1 LB/HR |
Moisture Removal @ 82°DB / 60% R.H.1 |
N/A 37.1 LB/HR |
Sensible Cooling @ 82°DB / 50% R.H.2 | N/A 44.8 MBH |
Sensible Cooling @ 82°DB / 60% R.H.2 |
N/A 39.7 MBH |
Weight |
N/A 750 LB |
External Static Pressure |
N/A 0.5 " H2O |
Refrigerant |
N/A R-454B (Factory Charged 40 lbs.) |
Compressor Type |
N/A Scroll |
Filter (Quantity: 2) |
N/A 20" x 25" x 1" Fiberglass |
Drain Connection |
N/A 1" Bar Drain |
Liquid Inlet [O.D.] (up to 50')3 | N/A 0.625 in |
Hot Gas Outlet [O.D.] (up to 50')3 |
N/A 0.875 in |
Note |
N/A Ratings are subject to change without notice |
- 1 Reheat Mode assuming 1050 BTU/lb
- 2 Cooling Mode with Remote Condenser at 95 °F
- 3 Over 50 ft contact factory