CAD (0)
▾
Air Cooled, non water heating assist dehumidifiers are used when there is a primary pool and spa water heating source such as a hot water boiler in place.Typical applications would include, but be limited to, small pool surface area projects or in coldclimates or both.
Unit of Measure
Available Model Configurations |
N/A DCA8000T: Air Cooled DCA8000T-CT: Water Cooled |
Standard Features |
N/A - 3 Year Parts Warranty - Dual Refrigeration Circuit - Dual Scroll Compressor - ElectroFin Coated Coils" - Low Ambient Head Pressure Control - MET Laboratory Safety Listed to UL 1995 - Motorized Evaporator Bypass Damper - Powder Coated, Galvannealed Steel Cabinet - Remote Condenser Ready - Rifle Tube Refrigeration Coils - Stainless Steel Condensate Drain Pan - Standard Microprocessor Control System (WH Models only) - TEFC Blower Motor |
Optional Features |
N/A - Control Options - Defrost Timer Package - External Static Upgrade - Other Options Available - Outdoor Installation Package - Outdoor Make Up Air Assembly with Damper & Filter - Remote Ready Delete - Right Side Component Service Access - Space Heating Options Available - Top or Bottom Discharge (Not Field Convertible) - Water Cooled Condenser for Water Heating or A/C Available |
Available Voltage/Phase |
N/A 208/230-3-60 460-3-60 575-3-60 |
Compressor @ 208/230-3-60 A/B |
N/A 106/106 RLA30.1/30.1 LRA225/225 BTU |
Blower Motor @ 208/230-3-60 |
N/A 5 hp22.4 Unit FLA |
Unit FLA @ 208/230-3-60 |
N/A 84.8 |
Maximum Fuse Size @ 208/230-3-60 |
N/A 110 |
Minimum Circuit Ampacity @ 208/230-3-60 |
N/A 92.3 |
Operating Power @ 208/230-3-60 |
N/A 21.06 kW |
Compressor @ 460-3-60 A/B |
N/A 106/106 RLA15.5/15.5 LRA114/114 BTU |
Blower Motor @ 460-3-60 |
N/A 7.5 hp10.8 Unit FLA |
Unit FLA @ 460-3-60 |
N/A 42.8 |
Maximum Fuse Size @ 460-3-60 |
N/A 60 |
Minimum Circuit Ampacity @ 460-3-60 |
N/A 46.7 |
Operating Power @ 460-3-60 |
N/A 20.83 kW |
Compressor @ 575-3-60 A/B |
N/A 106/106 RLA12.1/12.1 LRA80/80 BTU |
Blower Motor @ 575-3-60 |
N/A 7.5 hp8.5 Unit FLA |
Unit FLA @ 575-3-60 |
N/A 33.6 |
Maximum Fuse Size @ 575-3-60 |
N/A 45 |
Minimum Circuit Ampacity @ 575-3-60 |
N/A 36.6 |
Operating Power @ 575-3-60 |
N/A 20.73 kW |
CFM |
N/A 8000 |
Nominal Tonnage |
N/A 2 x 8.8 Dual Circuit |
Moisture Removal @ 82°DB / 50% R.H.1 | N/A 84.3 LB/HR |
Moisture Removal @ 82°DB / 60% R.H.1 |
N/A 108.7 LB/HR |
Sensible Cooling @ 82°DB / 50% R.H.2 | N/A 124.4 MBH |
Sensible Cooling @ 82°DB / 60% R.H.2 |
N/A 110.3 MBH |
Weight |
N/A 2500 LB |
External Static Pressure |
N/A 0.50 " H2O |
Refrigerant |
N/A R-407C (Factory Charged A/B 65 lbs.) |
Compressor Type |
N/A Dual Scroll |
Filter (Quantity: 6) |
N/A 20" x 25" x 4" Pleated |
Drain Connection |
N/A 1" Bar Drain |
Liquid Inlet A/B [O.D.] (up to 50') |
N/A 0.625/0.625 in |
Hot Gas Outlet A/B [O.D.] (up to 50')3 |
N/A 1.125/1.125 in |
Note |
N/A Ratings are subject to change without notice |
Optional Fresh Air and Discharge Openings |
N/A
DCA8000T with Optional Opening, Non Water Heating Assist Dehumidifier (Quote) |
with Indoor Hood (Indoor installation) |
N/A
DCA8000T with Indoor Hood, Non Water Heating Assist Dehumidifier (Quote) |
with Outdoor Hood (Outdoor installation) |
N/A
DCA8000T with Outdoor Hood, Non Water Heating Assist Dehumidifier (Quote) |
- 1 Reheat Mode assuming 1050 BTU/lb
- 2 Cooling Mode with Remote Condenser at 95 °F