CAD (0)
  • Cart is empty
Pool water heating assist dehumidifiers are well suited to projects that feature large pool surface areas such as are typical in commercial applications, and are located in warm climates where the operation of the dehumidifier would spend much of its time operating in remote condenser mode providing room cooling. Typically these applications must include a primary water heating source as well.
Unit of Measure

Available Model Configurations

N/A DCA1500TVWH: Air Cooled Water Heating Assist DCA1500TVWH-CT: Water Cooled Water Heating Assist

Standard Features

N/A - 3 Year Parts Warranty - ElectroFin Coated Coils - Low Ambient Head Pressure Control - MET Laboratory Safety Listed to UL 1995 - Powder Coated, Galvannealed Steel Cabinet - Remote Condenser Ready - Rifle Tube Refrigeration Coils - Single Refrigeration Circuit - Single Scroll Compressor - Stainless Steel Condensate Drain Pan - Standard Microprocessor Control System (WH Models only) - TEFC High Efficiency Blower Motor

Optional Features

N/A - Control Options - Defrost Timer Package - Extended Surface Filters 2" & 4" - External Static Upgrade - Horizontal Discharge (Not Field Convertible) - Motorized Evaporator Bypass Damper - Other Options Available - Outdoor Make Up Air Flange Opening (Damper & Filter by Others) - Remote Ready Delete - Right Side Return Air - Space Heating Options Available - Water Cooled Condenser for Water Heating or A/C Available
Available Voltage/Phase1 N/A 208/230-1-60 208/230-3-60 460-3-60 575-3-60

N/A  

Compressor @ 208/230-1-60

N/A 36,600 BTU19.2 RLA112 LRA

Blower Motor @ 208/230-1-60

N/A 1 hp6.4 Unit FLA

Unit FLA @ 208/230-1-60

N/A 27.0

Maximum Fuse Size @ 208/230-1-60

N/A 40

Minimum Circuit Ampacity @ 208/230-1-60

N/A 31.8

Operating Power @ 208/230-1-60

N/A 4.11 kW

N/A  

Compressor @ 208/230-3-60

N/A 36,900 BTU12.2 RLA93 LRA

Blower Motor @ 208/230-3-60

N/A 1 hp3.2 Unit FLA

Unit FLA @ 208/230-3-60

N/A 16.8

Maximum Fuse Size @ 208/230-3-60

N/A 25

Minimum Circuit Ampacity @ 208/230-3-60

N/A 19.9

N/A  

Compressor @ 460-3-60

N/A 36,900 BTU5.8 RLA48 LRA

Blower Motor @ 460-3-60

N/A 1 hp1.6 Unit FLA

Unit FLA @ 460-3-60

N/A 8.1

Maximum Fuse Size @ 460-3-60

N/A 12

Minimum Circuit Ampacity @ 460-3-60

N/A 9.6

Operating Power @ 460-3-60

N/A 3.98 kW

N/A  

Compressor @ 575-3-60

N/A 36,900 BTU4.4 RLA33 LRA

Blower Motor @ 575-3-60

N/A 1 hp1.5 Unit FLA

Unit FLA @ 575-3-60

N/A 6.5

Maximum Fuse Size @ 575-3-60

N/A 10

Minimum Circuit Ampacity @ 575-3-60

N/A 7.6

Operating Power @ 575-3-60

N/A 4.04 kW

CFM

N/A 1500

Nominal Tonnage

N/A 3
Moisture Removal @ 82°DB / 50% R.H.2 N/A 14.7 LB/HR

Moisture Removal @ 82°DB / 60% R.H.1

N/A 18.9 LB/HR
Sensible Cooling @ 82°DB / 50% R.H.3 N/A 21.6 MBH

Sensible Cooling @ 82°DB / 60% R.H.2

N/A 19.2 MBH
Water Flow4 N/A 6.0 GPM

Pressure Drop3

N/A 5.3

External Static Pressure

N/A 0.5 " H2O

Compressor Type

N/A Scroll

Filter (Quantity: 2)

N/A 18" x 25" x 1" Fiberglass

Drain Connection

N/A 1" Bar Drain
Liquid Inlet [O.D.] (up to 50')5 N/A 0.5 in

Hot Gas Outlet [O.D.] (up to 50')4

N/A 0.75 in

Water Inlet [O.D.]

N/A 0.875 in

Water Outlet [O.D.]

N/A 0.875 in

Weight

N/A 660 LB

Refrigerant

N/A R-407C (Factory Charged 20 lbs.)

Note

N/A Ratings are subject to change without notice
Water Heating Capacity @ 82°DB / 50% R.H. (MBH)6 N/A 46.2

Water Heating Capacity @ 82°DB / 60% R.H. (MBH)1

N/A 48.4
Water Flow (G.P.M.)7 N/A 6.0

Pressure Drop2

N/A 5.3
Water Heating Capacity @ 82°DB / 50% R.H. (MBH)8 N/A 46.2

Water Heating Capacity @ 82°DB / 60% R.H. (MBH)1

N/A 48.4
Water Flow (G.P.M.)9 N/A 6.0

Pressure Drop2

N/A 5.3
Water Temperature Range10 N/A 35°F to 85°F

Available Water Sources

N/A City Water Geothermal Loop Processed Water Water Tower

Optional Fresh Air and Discharge Openings

N/A , Water Heating Assist Dehumidifier (Quote)
  • 1 380V-3Ph-50Hz Available Upon Request
  • 2 Reheat Mode assuming 1050 BTU/lb
  • 3 Cooling Mode with Remote Condenser at 95 °F
  • 4 Water Flow data as used on 50% RH + Return Air 82 °F and Pool Water at 85 °F
  • 5 Over 50 ft contact factory
  • 6 Assuming 85 °F entering water temperature.
  • 7 Water Flow data as used on 50% RH + Return Air 82 °F and Pool Water at 85 °F
  • 8 Assuming 85 °F entering water temperature.
  • 9 Water Flow data as used on 50% RH + Return Air 82 °F and Pool Water at 85 °F
  • 10 Depends on a lot of factors, contact factory for details.