Air Cooled, non water heating assist dehumidifiers are used when there is a primary pool and spa water heating source such as a hot water boiler in place. Typical applications would include, but be limited to, small pool surface area projects or in cold climates or both.
Unit of Measure

Available Model Configurations

N/A DCA2000TV: Air Cooled DCA2000TV-CT: Water Cooled

Standard Features

N/A - 3 Year Parts Warranty - ElectroFin Coated Coils - Low Ambient Head Pressure Control - MET Laboratory Safety Listed to UL 1995 - Powder Coated, Galvannealed Steel Cabinet - Remote Condenser Ready - Rifle Tube Refrigeration Coils - Single Refrigeration Circuit - Single Scroll Compressor - Stainless Steel Condensate Drain Pan - Standard Microprocessor Control System (WH Models only) - TEFC High Efficiency Blower Motor

Optional Features

N/A - Control Options - Defrost Timer Package - Extended Surface Filters 2" & 4" - External Static Upgrade - Horizontal Discharge (Not Field Convertible) - Motorized Evaporator Bypass Damper - Other Options Available - Outdoor Make Up Air Flange Opening (Damper & Filter by Others) - Remote Ready Delete - Right Side Return Air - Space Heating Options Available - Water Cooled Condenser for Water Heating or A/C Available
Available Voltage/Phase1 N/A 208/230-1-60 208/230-3-60 460-3-60 575-3-60

N/A  

Compressor @ 208/230-1-60

N/A 46,200 BTU21.8 RLA137 LRA

Blower Motor @ 208/230-1-60

N/A 1.5 hp6.5 Unit FLA

Unit FLA @ 208/230-1-60

N/A 29.7

Maximum Fuse Size @ 208/230-1-60

N/A 45

Minimum Circuit Ampacity @ 208/230-1-60

N/A 35.2

Operating Power @ 208/230-1-60

N/A 5.02 kW

N/A  

Compressor @ 208/230-3-60

N/A 46,800 BTU15.4 RLA114 LRA

Blower Motor @ 208/230-3-60

N/A 1.5 hp4.8 Unit FLA

Unit FLA @ 208/230-3-60

N/A 21.6

Maximum Fuse Size @ 208/230-3-60

N/A 30

Minimum Circuit Ampacity @ 208/230-3-60

N/A 25.5

Operating Power @ 208/230-3-60

N/A 5.07 kW

N/A  

Compressor @ 460-3-60

N/A 46,800 BTU7.1 RLA58 LRA

Blower Motor @ 460-3-60

N/A 1.5 hp2.4 Unit FLA

Unit FLA @ 460-3-60

N/A 10.2

Maximum Fuse Size @ 460-3-60

N/A 17.5

Minimum Circuit Ampacity @ 460-3-60

N/A 12.0

Operating Power @ 460-3-60

N/A 5.08 kW

N/A  

Compressor @ 575-3-60

N/A 46,800 BTU5.2 RLA37 LRA

Blower Motor @ 575-3-60

N/A 1.5 hp1.9 Unit FLA

Unit FLA @ 575-3-60

N/A 7.7

Maximum Fuse Size @ 575-3-60

N/A 12

Minimum Circuit Ampacity @ 575-3-60

N/A 9.0

Operating Power @ 575-3-60

N/A 4.92 kW

CFM

N/A 2000

Nominal Tonnage

N/A 3.8
Moisture Removal @ 82°DB / 50% R.H.2 N/A 18.6 LB/HR

Moisture Removal @ 82°DB / 60% R.H.1

N/A 24.0 LB/HR
Sensible Cooling @ 82°DB / 50% R.H.3 N/A 27.5 MBH

Sensible Cooling @ 82°DB / 60% R.H.2

N/A 24.4 MBH

Weight

N/A 660 LB

External Static Pressure

N/A 0.50 " H2O

Refrigerant

N/A R-407C (Factory Charged 25 lbs.)

Compressor Type

N/A Scroll

Filter (Quantity: 2)

N/A 18" x 25" x 1" Fiberglass

Drain Connection

N/A 1" Bar Drain
Liquid Inlet [O.D.] (up to 50')4 N/A 0.5 in

Hot Gas Outlet [O.D.] (up to 50')3

N/A 0.75 in

Note

N/A Ratings are subject to change without notice

Optional Fresh Air and Discharge Openings

N/A , Air Cooled - Non Water Heating Dehumidifier (Quote)
  • 1 380V-3Ph-50Hz Available Upon Request
  • 2 Reheat Mode assuming 1050 BTU/lb
  • 3 Cooling Mode with Remote Condenser at 95 °F
  • 4 Over 50 ft contact factory