CAD (0)
▾
Air Cooled, non water heating assist dehumidifiers are used when there is a primary pool and spa water heating source such as a hot water boiler in place.Typical applications would include, but be limited to, small pool surface area projects or in coldclimates or both.
Unit of Measure
Available Model Configurations |
N/A DCA4800A: Air Cooled DCA4800A-CT: Water Cooled |
Standard Features |
N/A - 3 Year Parts Warranty - ElectroFin Coated Coils" - Low Ambient Head Pressure Control - MET Laboratory Safety Listed to UL 1995 - Motorized Evaporator Bypass Damper - Powder Coated, Galvannealed Steel Cabinet - Remote Condenser Ready - Rifle Tube Refrigeration Coils - Single Refrigeration Circuit - Single Scroll Compressor - Stainless Steel Condensate Drain Pan - Standard Microprocessor Control System (WH Models only) - TEFC Blower Motor |
Optional Features |
N/A - Control Options - Defrost Timer Package - ExtendedSurface Filters 2" & 4" - External Static Upgrade - Other Options Available - Outdoor Installation Package - Outdoor Make Up Air Assembly with Damper & Filter - Remote Ready Delete - Right Side Component Service Access - Space Heating Options Available - Top or Bottom Discharge (Not Field Convertible) - Water Cooled Condenser for Water Heating or A/C Available |
Available Voltage/Phase |
N/A 208/230-3-60 460-3-60 575-3-60 |
Compressor @ 208/230-3-60 |
N/A 123000 BTU33.3 RLA239 LRA |
Blower Motor @ 208/230-3-60 |
N/A 3 hp8.4 Unit FLA |
Unit FLA @ 208/230-3-60 |
N/A 43.4 |
Maximum Fuse Size @ 208/230-3-60 |
N/A 70 |
Minimum Circuit Ampacity @ 208/230-3-60 |
N/A 51.7 |
Operating Power @ 208/230-3-60 |
N/A 11.79 kW |
Compressor @ 460-3-60 |
N/A 123000 BTU17.9 RLA125 LRA |
Blower Motor @ 460-3-60 |
N/A 3 hp3.9 Unit FLA |
Unit FLA @ 460-3-60 |
N/A 22.6 |
Maximum Fuse Size @ 460-3-60 |
N/A 40 |
Minimum Circuit Ampacity @ 460-3-60 |
N/A 27.1 |
Operating Power @ 460-3-60 |
N/A 11.60 kW |
Compressor @ 575-3-60 |
N/A 121000 BTU12.8 RLA80 LRA |
Blower Motor @ 575-3-60 |
N/A 3 hp3.20 Unit FLA |
Unit FLA @ 575-3-60 |
N/A 16.7 |
Maximum Fuse Size @ 575-3-60 |
N/A 30 |
Minimum Circuit Ampacity @ 575-3-60 |
N/A 19.9 |
Operating Power @ 575-3-60 |
N/A 11.76 kW |
CFM |
N/A 4800 |
Nominal Tonnage |
N/A 10.30 |
Moisture Removal @ 82°DB / 50% R.H.1 | N/A 46.7 LB/HR |
Moisture Removal @ 82°DB / 60% R.H.1 |
N/A 60.2 LB/HR |
Sensible Cooling @ 82°DB / 50% R.H.2 | N/A 71.6 MBH |
Sensible Cooling @ 82°DB / 60% R.H.2 |
N/A 63 MBH |
Weight |
N/A 1320 LB |
External Static Pressure |
N/A 0.50 " H2O |
Refrigerant |
N/A R-410A (Factory Charged 65 lbs.) |
Compressor Type |
N/A Scroll |
Filter (Quantity: 4) |
N/A 20" x 25" x 1" Fiberglass |
Drain Connection |
N/A 1" Bar Drain |
Liquid Inlet [O.D.] (up to 50')3 | N/A 0.75 in |
Hot Gas Outlet [O.D.] (up to 50')3 |
N/A 1.13 in |
Note |
N/A Ratings are subject to change without notice |
Optional Fresh Air and Discharge Openings |
N/A
DCA4800A with Optional Opening, Non Water Heating Assist Dehumidifier (Quote) |
with Indoor Hood (Indoor installation) |
N/A
DCA4800A with Indoor Hood, Non Water Heating Assist Dehumidifier (Quote) |
with Outdoor Hood (Outdoor installation) |
N/A
DCA4800A with Outdoor Hood, Non Water Heating Assist Dehumidifier (Quote) |
- 1 Reheat Mode assuming 1050 BTU/lb
- 2 Cooling Mode with Remote Condenser at 95 °F
- 3 Over 50 ft contact factory